What Is NVL72?_

NVIDIA GB200 NVL72 and GB300 NVL72 are liquid-cooled, rack-scale systems that each combine 72 GPUs and 36 NVIDIA Grace CPUs in a 72-GPU NVLink domain. GB200 uses Blackwell GPUs; GB300 uses Blackwell Ultra GPUs. Here, 72 identifies the GPU count in those named configurations, not a universal rack size, power rating or installation work package.

Technical Details

NVIDIA publishes separate GB200 NVL72 and GB300 NVL72 product descriptions. Keep the generation and complete platform name attached to the specification. A liquid-cooled platform description does not establish the split of heat captured by the liquid loop, a site cooling design or cooling acceptance. Confirm the actual supplier/OEM configuration, applicable document revision, physical interfaces and approved installation package. Do not transfer power, weight or cable quantities from another configuration; the responsible system and facility owners must resolve the actual requirements.

Sources

  • NVIDIA GB200 NVL72 product overview

    Checked 2026-10-16. Named rack-scale system example only; no power, cooling percentage, weight, cable count, performance or availability conclusion adopted.

  • NVIDIA GB300 NVL72 product overview

    Checked 2026-10-16. Named rack-scale system example only; no universal NVL72 specification, delivery claim or installation procedure adopted.

How Leviathan Systems Works with NVL72

For an identified NVL72 system, Leviathan can discuss a separately agreed physical mounting, external IT cabling, labeling and documentation package after the actual OEM configuration and site requirements are identified. Work remains subject to authorized scope and team availability. Identify the appointed equipment/material supplier, approved configuration, quantities and delivery responsibilities before agreeing the physical work. Liquid-side work and facility electrical installation remain excluded; full system/software commissioning is not a standard service.

Appears In

CUDA Fabric Memory: Allocation Handles, Local Maps and Device AccessData Center GPUs by Memory Capacity: Compare the Exact VariantGPU Storage Network Handoff: Trace the Physical ConnectionsData Center Drawing Releases: Keep Revision and Workfront TogetherWarm-Water Cooling for GPU Clusters: Why Hotter Water WinsThermal Soak & Burn-In During Commissioning: What to WatchVera Rubin NVL72 Readiness: Confirm the System and Its InterfacesMEP Coordination for AI Data Halls: Where Mechanical, Electrical, and IT CollideGPU Data Center Deployment in Phoenix, Arizona: Hiring the Build CrewGPU Data Center Deployment in Ohio: Staffing the Physical BuildGB200 NVL72 Deployment Deep Dive: Liquid Loop, Busbar, and SpineGPU Rack Floor Loading: Read the Rating Before Comparing the WeightB300 Deployment Planning: Identify the System and Its Power OptionGPU Installation Handoff: Records, Revisions and Open ItemsB200 vs GB200: GPU, HGX, DGX and NVL72 Names ExplainedNVIDIA GB300 NVL72 Explained: Specs, Power, and What It Takes to DeployHow to Choose a Data Center Liquid Cooling CompanyWho Deploys GB200 and GB300 NVL72? Assign the Work Before Choosing the TeamWhy Data Center Projects Take Time: Facility Readiness and GPU DeploymentGPU Data Center Deployment in Texas: Who Does It and How to HireNVLink Cable Cartridges: Identify the Assembly Before Assigning WorkGB300 NVL72 Deployment: Power, Cooling, and the Cable PlantDGX GB200 vs DGX GB300: NVL72 Network InterfacesGPU Rack Receiving and Movement: Prepare the Review PackageOverhead Busway Installation for 100kW+ GPU Rack Drops