LEVIATHAN SYSTEMS
Topic

Network Architecture_

The network fabric connecting GPUs is as critical as the GPUs themselves. A poorly designed or improperly cabled network turns a $50 million GPU cluster into an underperforming asset. AI training workloads are communication-intensive: distributed training requires constant synchronization across hundreds or thousands of GPUs, and network bottlenecks directly translate to wasted compute cycles and longer training times.

Leviathan Systems Scope_

Leviathan Systems installs and tests the physical network infrastructure for GPU clusters, including InfiniBand NDR/XDR cabling, 400GbE Ethernet fabric, NVLink Switch configurations, and management networks. Our network testing validates throughput, latency, and error rates before the cluster enters production.

Articles_

Transceiver Breakout & Splitter Cabling for GPU FabricsDetails field procedures for deploying 2x and 4x breakout cables from high-speed switch ports to GPU NICs in scale-out InfiniBand or Ethernet fabrics, covering selection, routing, testing, and failure avoidance for GPU cluster deployments.NVIDIA Spectrum-X vs Quantum InfiniBand: The Cabling and Optics ViewThis article compares Spectrum-X Ethernet and Quantum InfiniBand fabrics strictly through the cabling, optics, and topology tasks performed by field crews during NVL72-class rack deployments, including switch port mapping, MPO trunk routing, and link validation steps.Optical Transceiver Handling & Cleanliness on the FloorDetails ESD controls, dust cap discipline, end-face inspection, and insertion sequences that prevent contamination and damage in 400G+ scale-out optics during rack integration and acceptance testing.Back-End vs Front-End Network Build-Out for GPU ClustersDetails the physical and logical separation of intra-rack copper NVLink backplanes from inter-rack MPO-based scale-out fabrics in H100-to-GB300 NVL72 deployments, including routing rules, test sequences, and field failure patterns that affect commissioning timelines.Building the Leaf-Spine Cable Plant for a GPU FabricDetails the physical leaf-spine fiber plant construction for AI scale-out fabrics, covering trunk routing, polarity control, inspection sequences, and verification steps that crews follow when connecting GPU racks via InfiniBand or Ethernet.InfiniBand NDR/XDR vs RoCE: What Changes for the Cable PlantDetails how choosing InfiniBand NDR/XDR versus RoCE for the scale-out fabric changes MPO trunk selection, patching sequences, cleaning protocols, and test parameters during rack deployment and inter-rack cabling for GPU clusters.Validating an InfiniBand Fabric with ibdiagnet: Errors, Width, and RoutingThis article details the exact ibdiagnet command sequence and output checks required to confirm every InfiniBand scale-out link in an NVL72-class deployment trains at full width and speed before cluster handover.400G vs 800G vs 1.6T Optics: Selecting Transceivers for AI FabricThis article gives deployment engineers explicit criteria for matching 400G/800G/1.6T transceivers to switch ports, fiber reach, and MPO infrastructure in AI scale-out fabrics while keeping NVLink copper domains separate.Rail-Optimized vs Fat-Tree: The Field Wiring Plan, Port by PortA field engineer's definitive guide to physically wiring and patching rail-optimized versus fat-tree InfiniBand/Ethernet fabrics in AI data centers, port by port, including common failure modes and testing procedures.Spectrum-X vs InfiniBand: What's Different for the Cable PlantA field engineer’s practical breakdown of how Spectrum-X and InfiniBand back-end networks differ for the cable plant in AI data centers, focusing on optics, fiber types, and installer workflow—and why the differences are smaller than most expect.

Ready to Deploy Your GPU Infrastructure?_

Tell us about your project. Book a call and we’ll discuss scope, timeline, and the best approach for your deployment.

Book a Call