Compare the complete server configurations, not a GPU name alone. Dell's XE9680 guide documents a 6U air-cooled server with separate eight-GPU MI300X OAM 2.0 and HGX H100 SXM5 options. That shared system family does not establish an approved conversion between them. Compare the offered accelerator set, OEM hardware configuration and supported software stack before deciding what the installation requires.

## Hold the OEM system family constant

A useful MI300X-versus-H100 comparison starts with an actual server example. Dell's PowerEdge XE9680 Technical Guide, July 2025 Rev. A09, describes the system as a 6U air-cooled rack server. Its overview lists an AMD Instinct MI300X eight-GPU OAM 2.0 option and an NVIDIA HGX H100 eight-GPU SXM5 option. The guide also covers other accelerators; the table below isolates these two rather than treating every listed option as the same configuration.

This matters because a rule such as H100 means 4U while MI300X means 6U cannot describe all systems. In this named OEM family, the chassis height is the same. That does not establish equal input power, identical accessories, a supported accelerator swap or suitability for a particular facility. Those questions require the offered configuration and its applicable OEM documents.

Use the comparison to separate a documented product property from an assumption. A current product page or manual is evidence of the described design, not a stock, delivery-date or price commitment.

References: [D1](https://www.delltechnologies.com/asset/en-ca/products/servers/technical-support/poweredge-xe9680-technical-guide.pdf)

Two accelerator options documented for Dell PowerEdge XE9680
| Comparison item | MI300X option | H100 option | Source |
| --- | --- | --- | --- |
| Named complete system | PowerEdge XE9680; 6U rack server | PowerEdge XE9680; 6U rack server | D1 |
| Accelerator group listed by Dell | Eight AMD Instinct MI300X GPUs; OAM 2.0 | Eight H100 SXM5 GPUs in the HGX H100 configuration | D1 |
| Cooling classification in the cited overview | XE9680 is described as air-cooled | XE9680 is described as air-cooled | D1 |
| Product-name distinction to preserve | MI300X OAM versus the AMD eight-OAM reference platform versus the complete server | H100 SXM versus the separately specified H100 NVL variant | A1, N1 |
| Software reference to check | Applicable ROCm hardware/environment and framework compatibility | Applicable CUDA release and host-environment requirements | A2, N2 |
Named documentation example, not a performance test or a configuration-conversion guide. The actual OEM offer must identify its supported hardware, cooling, software and site requirements. This comparison is not a product quotation. This comparison does not establish OEM authorization or availability of these exact configurations. Identify the appointed supplier and delivery responsibilities in the project scope.

## Separate the module, platform and complete server

AMD identifies its MI300X Platform as an Instinct Platform using UBB 2.0 with eight MI300X OAMs. That is a platform-level description. Its published dimensions do not describe the complete Dell chassis, rail kit, external connectors or service clearances. Likewise, an H100 GPU specification does not describe every enclosure built around it.

NVIDIA's H100 product table distinguishes H100 SXM from the PCIe-form-factor H100 NVL. Dell's cited XE9680 option names HGX H100 and SXM5. Keep that variant visible in the equipment line; a comparison that silently substitutes NVL would be answering a different hardware question.

Memory capacity is another product-level question. Use the separate GPU-memory guide when comparing advertised device and platform totals. For the physical build, obtain the complete server configuration. Neither a memory total nor a GPU component rating establishes the node's full input requirement, rack population or facility cooling acceptance.

References: [A1](https://www.amd.com/en/products/accelerators/instinct/mi300/platform.html), [N1](https://www.nvidia.com/en-us/data-center/h100/), [D1](https://www.delltechnologies.com/asset/en-ca/products/servers/technical-support/poweredge-xe9680-technical-guide.pdf)

## Keep the GPU fabric separate from network options

AMD's MI300 architecture documentation describes Infinity Fabric links within its MI300X reference node. NVIDIA describes NVLink for H100. These are accelerator-interconnect descriptions. AMD's illustrated reference node is not a wiring drawing for the Dell server; use the complete OEM configuration to identify the internal hardware being supplied.

The external network needs its own evidence. Identify the selected adapter models, populated ports, connector or optic requirements and intended endpoints. Do not derive an MPO trunk quantity or a rule of twice as many network ports from the GPU brand. Dell's system overview lists expansion options, not a universal scale-out cable count for every XE9680.

If a proposed H100 and MI300X package share the same cabinet location, ask whether their actual external interfaces also match. A cable-reuse decision needs those endpoints and approved requirements. It is not settled by both offers containing eight GPUs or using the same server family name.

References: [A3](https://rocmdocs.amd.com/en/docs-7.2.4/conceptual/gpu-arch/mi300.html), [N1](https://www.nvidia.com/en-us/data-center/h100/), [D1](https://www.delltechnologies.com/asset/en-ca/products/servers/technical-support/poweredge-xe9680-technical-guide.pdf)

## Treat software confirmation as a buying input

A hardware comparison is incomplete if the application owner cannot identify the supported software configuration it intends to use. AMD's ROCm compatibility documentation describes a coordinated firmware, driver and user-space stack and release-specific hardware, operating-system and framework support. NVIDIA's CUDA Linux guide likewise qualifies support against the host environment for the selected Toolkit release.

Ask the application or platform owner which framework, model, precision, extensions and runtime versions were evaluated on the proposed system. If the current workload depends on a particular software component, identify the supported path for the alternative platform and what still needs validation. A compatibility-table entry is not a measured result for that workload.

Keep the evidence comparable when performance affects the choice. The model, accuracy requirement, precision, software, participating hardware and latency or throughput target belong with any claimed result. This article supplies no MI300X-versus-H100 benchmark or universal winner; the workload-comparison guide explains how to read that evidence.

References: [A2](https://rocm.docs.amd.com/en/latest/compatibility/compatibility-matrix.html), [N2](https://docs.nvidia.com/cuda/cuda-installation-guide-linux/index.html)

## Resolve an incomplete equipment line

Illustrative example: one equipment list says XE9680 with eight MI300X GPUs, while another says XE9680 with eight H100s. Both descriptions point toward the documented system family, but neither is a complete approved equipment package. The H100 line still needs its exact variant; both need the selected OEM configuration and supplied options. This is a hypothetical buyer comparison.

Use the following questions to close specific gaps in the supplier's description. The table does not select replacement parts or create a bill of materials for purchase. Obtain actual configuration identifiers and documents from the party supplying and supporting the system.

Questions for two incomplete server offers
| Missing detail | What to obtain | Why it changes the comparison | Source |
| --- | --- | --- | --- |
| Exact accelerator configuration | OEM configuration identifier and explicitly named GPU variant/group | A family name alone does not establish a supported conversion or interchangeable components. | Planning analysis |
| External network package | Selected adapters, populated port list and the approved connection/optic requirements | The physical cable schedule follows these interfaces, not a brand-based multiplier. | Planning analysis |
| Rack and facility interfaces | Actual OEM dimensions/accessory records and the qualified site disposition for the offered configuration | The documented 6U height does not settle service access, rack suitability, power or thermal requirements. | Planning analysis |
| Software target | Applicable supported software versions and the application owner's workload evidence or unresolved validation | Documented hardware support is not proof that the buyer's application is ready on the alternative platform. | Planning analysis |
Original buyer-analysis questions. No real customer order, part number, tested workload, site approval or technical operating method is represented.

## Compare named complete servers before scaling the rack

There are two different comparisons to make. Holding Dell's XE9680 family constant isolates two accelerator options within a 6U air-cooled system family. Comparing a Dell MI300X configuration with NVIDIA's own DGX H100 changes the complete server as well as the accelerator. NVIDIA documents the DGX H100 as an eight-H100 system with an 8U enclosure. The second comparison therefore has a different physical result without establishing that AMD systems are universally smaller.

Keep the product level on each equipment line. AMD's eight-OAM UBB 2.0 platform identifies an accelerator assembly; it does not supply the complete server enclosure height. A complete OEM server description supplies that next level of information. A rack installation package then has to account for the selected servers and the other equipment and interfaces around them. An eight-GPU platform, an eight-GPU server and a populated rack are not interchangeable delivery units.

The comparison below uses published design descriptions, not current supplier quotations. It does not establish interchangeable hardware, equivalent application performance or which system is the better purchase. The buyer still needs the exact offered configuration, its applicable documents and the supplying party's description of what is delivered assembled and what remains to be provided or connected.

References: [A1](https://www.amd.com/en/products/accelerators/instinct/mi300/platform.html), [D1](https://www.delltechnologies.com/asset/en-ca/products/servers/technical-support/poweredge-xe9680-technical-guide.pdf), [N3](https://docs.nvidia.com/dgx/dgxh100-user-guide/introduction-to-dgxh100.html)

An AMD-equipped OEM server and a named NVIDIA complete system
| Comparison item | Dell XE9680 MI300X option | NVIDIA DGX H100 | Source |
| --- | --- | --- | --- |
| Complete system used in this comparison | Dell PowerEdge XE9680 with the documented MI300X configuration | NVIDIA DGX H100, rather than an unspecified H100 server | D1, N3 |
| Accelerator population | Eight MI300X GPUs in the OAM 2.0 option listed by Dell | Eight H100 GPUs in the named DGX system | D1, N3 |
| Published complete-server height | 6U for the cited XE9680 system family | 8U for the cited DGX H100 system | D1, N3 |
| What that server height does not describe | An entire rack or every MI300X enclosure; AMD's UBB platform is a different product level | An entire rack or every OEM server containing H100 GPUs | A1, D1, N3 |
| Inputs needed beyond the product summary | Exact offered configuration, OEM installation requirements, supplied accessories and actual external interfaces | Exact ordered system, applicable installation requirements, supplied accessories and actual external interfaces | Planning analysis |
This is a named product comparison, not a released rack layout, supplier offer, cable list, performance benchmark or installation method. The existing same-XE9680 comparison above remains valid: the cited H100 option in that family is also 6U. A brand-wide height rule would contradict that example.

## Count server space without declaring a rack ready

Fictional planning example EX-AM97: a buyer requests a population of 32 GPUs, with every GPU supplied inside one of the named eight-GPU complete servers. This is a count target, not a claim that 32 MI300X GPUs and 32 H100 GPUs deliver equivalent work. Under that stated assumption, either option requires four servers. Four cited XE9680 enclosures sum to 24U; four cited DGX H100 enclosures sum to 32U. The eight-unit difference is a difference in these server-height sums, not eight units of approved spare capacity or evidence that either option fits one rack.

The calculation has not counted network or management switches, storage, panels, other rack equipment or required space around the equipment. It also has no disposition for the actual cabinet, rails, depth, load, service access, power or cooling interfaces. Do not turn the server-height sum into a rack quantity or installation release. Return those questions to the responsible equipment and site owners with the exact configurations being compared.

For the delivery discussion, keep the four server identities and the surrounding package separate. Ask whether the offer is for individual complete servers or an integrated rack, who supplies the rack and accessories, which adapters and external connections are actually populated, and which documents identify the delivered state. A supplier's proposed integrated rack needs its own equipment and interface record; it is not created by writing four server lines under one rack heading. The installation scope can then refer to the actual delivered objects and permitted remaining work instead of assuming an assembly state from the GPU brand.

References: [D1](https://www.delltechnologies.com/asset/en-ca/products/servers/technical-support/poweredge-xe9680-technical-guide.pdf), [N3](https://docs.nvidia.com/dgx/dgxh100-user-guide/introduction-to-dgxh100.html)

EX-AM97: server-count arithmetic with an explicit stopping point
| Fictional comparison field | XE9680 MI300X option | DGX H100 option | Source |
| --- | --- | --- | --- |
| Specified GPU population | 32 GPUs; fictional buyer input | 32 GPUs; the same count input, not a performance equivalence | Planning analysis |
| Complete servers under the eight-GPU assumption | 32 divided by 8 = 4 servers | 32 divided by 8 = 4 servers | D1, N3 |
| Sum of published server heights only | 4 times 6U = 24U | 4 times 8U = 32U | D1, N3 |
| Released rack count and approved surrounding package | Not determined by this example | Not determined by this example | Planning analysis |
Original illustrative arithmetic using named published server facts. Four servers per alternative are hypothetical; no actual equipment order, rack capacity, integration service, performance result, site approval or installation permission is represented.

## Compare MI325X and MI300X at the same product level

MI325X is a distinct accelerator product within AMD's MI300 series. The current AMD product pages identify both MI300X and MI325X as OAM modules with a PCIe 5.0 x16 interface. They list 192 GB of HBM3 for MI300X and 256 GB of HBM3E for MI325X. Those are accelerator-attached memory capacities, not the system's host memory or a promise of a single application-addressable pool. The shared module description does not establish a supported exchange inside an existing OEM server.

The power fields also differ. Under Typical Board Power (TBP), AMD lists 750W Peak for MI300X and 1000W Peak for MI325X. Preserve the board-level label and the peak qualifier when comparing them. Neither figure is a complete-server AC input value, a measured workload draw or an installation load allowance. The supplied server also contains CPUs, host memory, adapters and other components, and its OEM requirements govern the actual configuration. A larger board-level field is a reason to reopen the configuration assessment; it does not prove that a particular existing facility needs a prescribed upgrade.

AMD describes both modules' cooling as Passive OAM. That component description does not classify every complete server as air cooled or liquid cooled. A module, the baseboard that carries it, and the OEM enclosure with its actual cooling implementation are different product levels. In particular, sharing an OAM designation and host-bus generation does not prove that the board, power delivery, cooling assembly, firmware, rails or external interfaces can be retained. There is no component-exchange procedure or compatibility conclusion here.

A useful comparison therefore preserves both the changed fields and the unchanged ones. The GPU identity, attached memory and published board-power entry differ; the cited module form factor and bus description match. Treating every field as unchanged would miss real planning inputs. Treating every field as changed would invent work that the product pages do not establish. Move from this accelerator comparison to an exact supported OEM configuration before choosing a physical installation scope.

References: [A4](https://www.amd.com/en/products/accelerators/instinct/mi300/mi300x.html), [A5](https://www.amd.com/en/products/accelerators/instinct/mi300/mi325x.html)

Published accelerator fields: MI300X versus MI325X
| Field and product level | AMD MI300X | AMD MI325X | Planning implication | Source |
| --- | --- | --- | --- | --- |
| GPU module form factor | OAM Module | OAM Module | Same published module category; no drop-in or server conversion approval. | A4, A5 |
| Dedicated memory on one accelerator | 192 GB HBM3 | 256 GB HBM3E | Changed accelerator memory specification; neither is host RAM or proven usable application capacity. | A4, A5 |
| AMD Typical Board Power (TBP) entry | 750W Peak | 1000W Peak | Changed board-level peak entry; no complete-server or facility-load value. | A4, A5 |
| Published host-bus description | PCIe 5.0 x16 | PCIe 5.0 x16 | A matching interface description does not settle OEM configuration support or accessories. | A4, A5 |
| Module cooling description | Passive OAM | Passive OAM | Obtain the selected complete server's actual thermal arrangement; do not infer it from this field. | A4, A5 |
Current AMD product fields checked 19 October 2026. No performance, price, availability, link-count, application result, conversion method or site approval is inferred.

## Carry the accelerator comparison into a named OEM system

HPE's 10 October 2024 XD685 announcement supplies a concrete complete-server example: it describes a 5U family with eight MI325X or MI300X accelerators and air or direct liquid cooling options. This is a dated family-level description, not a current quotation or proof that every listed accelerator and cooling combination is offered together. It demonstrates why a changed accelerator does not automatically prescribe a taller enclosure, while a common family height does not establish an identical thermal or electrical package. The retained Dell XE9680 MI300X example above is a different complete system; its 6U description must not be copied onto an HPE offer.

Consider fictional EX-MX147. A buyer is comparing two alternative sixteen-accelerator populations, each stipulated to arrive inside two complete eight-accelerator servers from the cited HPE family. The alternatives are not four servers in one combined order, and the sixteen modules are not sixteen separately commissioned installation tasks. Two copies of the announcement's 5U enclosure description sum to 10U of server height in either alternative. This is not a released rack layout or a finding that the actual offered configurations have the same accessories, service space, load, power or cooling interfaces.

Using only the cited AMD per-accelerator fields, sixteen MI300X memory capacities sum to 3,072 GB and sixteen MI325X capacities sum to 4,096 GB. These are aggregate nameplate capacities across sixteen devices, not a single usable memory pool or evidence of equivalent workload delivery. The respective board-level peak entries sum to 12 kW and 16 kW. Their 4 kW numerical difference is not a measured energy saving, server-input delta, facility demand calculation or cooling requirement. In particular, it does not include the rest of either complete server.

The useful decision is which physical basis can be carried forward and which must be returned by the OEM or supplying party. The comparison has established two servers per hypothetical alternative and has identified changed accelerator fields. It has not selected an actual cooling option, populated adapter set or supported conversion. Keep the old installed server identity separate from the proposed supplied server, then obtain the exact configuration's installation and interface requirements. If the offer is an integrated rack, identify that delivered rack and the remaining work separately; two complete-server entries do not themselves describe an integrated rack. This lets the physical scope name the actual delivered objects and affected interfaces without claiming permission to modify the existing machines.

References: [A4](https://www.amd.com/en/products/accelerators/instinct/mi300/mi300x.html), [A5](https://www.amd.com/en/products/accelerators/instinct/mi300/mi325x.html), [H1](https://www.hpe.com/us/en/newsroom/press-release/2024/10/hpe-launches-new-purpose-built-solutions-powered-by-amd-to-accelerate-training-for-large-complex-ai-models.html), [D1](https://www.delltechnologies.com/asset/en-ca/products/servers/technical-support/poweredge-xe9680-technical-guide.pdf)

EX-MX147: two alternative populations, with explicitly limited arithmetic
| Comparison field | MI300X alternative | MI325X alternative | What remains unestablished | Source |
| --- | --- | --- | --- | --- |
| Stipulated accelerator and server population | 16 accelerators in 2 complete eight-accelerator servers | 16 accelerators in 2 complete eight-accelerator servers | No actual order, installation task count or equivalent workload capacity. | H1 |
| Sum of the cited HPE family enclosure heights | 2 times 5U = 10U | 2 times 5U = 10U | Actual offered configuration, rack arrangement, accessories, service access and site suitability. | H1 |
| Sum of attached memory capacity fields | 16 times 192 GB = 3,072 GB | 16 times 256 GB = 4,096 GB | No single application memory pool, host-memory capacity or workload result. | A4, A5 |
| Sum of board-level peak power entries only | 16 times 750W = 12 kW | 16 times 1000W = 16 kW | Actual complete-server input, operating load, energy use and facility thermal/electrical design. | A4, A5 |
| Selected OEM cooling and external-interface package | Not supplied in this fictional comparison | Not supplied in this fictional comparison | The responsible OEM and supplier must return the applicable actual configuration before physical scope is released. | Planning analysis |
Original fictional buyer arithmetic. The 2024 HPE announcement is a dated product-family example, not current availability, a purchased BOM, a blanket cooling-option matrix or an approved server conversion.

## Move the selected server into a physical work package

Once the actual server option is identified, send the full model and configuration, quantities, customer-provided accessories, approved rack positions and connection records for the physical installation discussion. Identify the OEM and platform contacts for work beyond that package. This gives the installation team a defined object to mount and connect instead of an accelerator label to interpret.

Leviathan delivers customer-supplied equipment mounting, rack-and-stack, structured cabling, labeling and agreed physical verification and records. Identify the equipment/material supplier, approved configuration, quantities and delivery responsibilities before agreeing the physical work. Liquid-cooling installation, facility electrical and mechanical work and cluster software commissioning stay with the OEM, the facility and the platform teams. The customer-furnished-materials guide helps reconcile what the supplier will actually deliver before physical work is scheduled.

References: [L1](https://www.leviathansystems.co/services/gpu-assembly)

## Common planning questions

### Does MI300X always need a taller or liquid-cooled server than H100?

The GPU name cannot establish that rule. Dell's cited XE9680 overview describes a 6U air-cooled server and lists both an eight-MI300X OAM 2.0 option and an eight-HGX-H100 SXM5 option. Other complete server designs have their own requirements. Confirm the actual offered configuration and site suitability rather than transferring a cooling or height assumption between systems.

### Can an H100 XE9680 be converted to MI300X by exchanging the GPUs?

The list of accelerator options does not establish an approved conversion. Ask Dell or the authorized system supplier whether the exact existing and proposed configurations support the requested change and what their supported scope is. This guide provides no component-replacement method or assurance that rails, boards, power, cooling or network options can be retained.

### Does MI300X require an AMD EPYC host CPU?

Do not infer a universal host-CPU requirement from the accelerator brand or a reference diagram. Dell's cited XE9680 guide lists Intel Xeon host-processor options and an AMD MI300X accelerator option within that server family. Confirm the OEM-supported combination for the actual offer; the guide's option list is not permission to combine arbitrary parts.

### Which is faster for my model, MI300X or H100?

The configuration table here does not answer a workload-performance question. Request evidence for the actual model, precision and accuracy requirement, software stack, hardware count and latency/throughput target. Keep advertised capacity and theoretical specifications separate from measured application results. The related benchmark-comparison guide explains those distinctions; no generic winner is asserted here.

### Does MI325X's higher board-power entry prove that the complete server is larger or needs a specific cooling upgrade?

No. AMD's board-level peak field differs from MI300X, but server height, actual input power and cooling depend on the selected OEM configuration. The dated HPE XD685 example describes one 5U family with both accelerator options; it does not establish a current offer or interchangeable configurations. Obtain the actual server requirements rather than turning a module field into a site design.

### Can an existing MI300X server accept MI325X because both accelerators are OAM modules?

A shared module category and PCIe generation do not establish an OEM-supported exchange. The actual server's supported accelerator, board, power, thermal, firmware and accessory configuration must be confirmed for the proposed change. This article compares published product fields and supplies no component-replacement or conversion method.

## Primary sources

- [D1 — Dell PowerEdge XE9680 Technical Guide, July 2025 Rev. A09: System overview, page 5](https://www.delltechnologies.com/asset/en-ca/products/servers/technical-support/poweredge-xe9680-technical-guide.pdf). Checked 2026-10-15. Exact XE9680 overview only: 6U air-cooled system, host processor options and separately listed eight-GPU configurations. Edition read from cover, relevant page rendered/inspected. No availability, interchangeability, site-fit or operating-method approval.
- [A1 — AMD Instinct MI300X Platform: product basics](https://www.amd.com/en/products/accelerators/instinct/mi300/platform.html). Checked 2026-10-15. UBB 2.0 reference-platform and eight-OAM identity only. Platform dimensions, capacities, performance or peer-bandwidth values are not substituted for a complete OEM server or benchmark.
- [A3 — AMD ROCm 7.2.4 documentation: MI300 Series node-level architecture](https://rocmdocs.amd.com/en/docs-7.2.4/conceptual/gpu-arch/mi300.html). Checked 2026-10-15. MI300X reference-node Infinity Fabric naming only; depicted EPYC-based reference is not claimed to be the Dell Intel-based server. No diagram copied or link count/rate prescribed.
- [N1 — NVIDIA H100: product specifications](https://www.nvidia.com/en-us/data-center/h100/). Checked 2026-10-15. H100 SXM versus H100 NVL product/form-factor distinction and NVLink naming only. No marketing performance, TCO, latency, memory-ranking or availability claim adopted.
- [A2 — AMD ROCm: compatibility matrix](https://rocm.docs.amd.com/en/latest/compatibility/compatibility-matrix.html). Checked 2026-10-15. Current matrix explains coordinated firmware/driver/user-space and version-specific GPU/OS/framework support. No exact customer software configuration, porting outcome or workload performance is verified.
- [N2 — NVIDIA CUDA Installation Guide for Linux: system requirements](https://docs.nvidia.com/cuda/cuda-installation-guide-linux/index.html). Checked 2026-10-15. Release-specific supported distribution/host-environment boundary only. No install commands, tuning, operating procedure or assertion that a customer application has been validated.
- [L1 — Leviathan GPU equipment installation scope](https://www.leviathansystems.co/services/gpu-assembly). Checked 2026-10-15. Physical-installation scope.
- [N3 — NVIDIA DGX H100/H200 User Guide: introduction, component and mechanical specifications](https://docs.nvidia.com/dgx/dgxh100-user-guide/introduction-to-dgxh100.html). Checked 2026-10-19. DGX H100 named complete-system identity, eight-H100 population and 8U form factor only. H200 values, power, weight, performance, installation steps and operating instructions are not adopted. Published server height does not establish a rack configuration, site suitability, equivalent workload capacity, supplied accessories or actual support and installation authority.
- [A4 — AMD Instinct MI300X: accelerator memory, board and interface fields](https://www.amd.com/en/products/accelerators/instinct/mi300/mi300x.html). Checked 2026-10-19. Named MI300X OAM, PCIe5x16,192GBHBM3,750WPeak TBP and PassiveOAM fields only. Board entries are not server/facility loads, usable pooled memory, benchmark, stock or compatibility approval; external-link counts and field procedures excluded.
- [A5 — AMD Instinct MI325X: accelerator memory, board and interface fields](https://www.amd.com/en/products/accelerators/instinct/mi300/mi325x.html). Checked 2026-10-19. Named MI325X OAM, PCIe5x16,256GBHBM3E,1000WPeak TBP and PassiveOAM fields only. No server power, actual load, memory pooling, external-link count, conversion, performance, availability or OEM/site approval.
- [H1 — HPE, 10 October 2024: XD685 family announcement](https://www.hpe.com/us/en/newsroom/press-release/2024/10/hpe-launches-new-purpose-built-solutions-powered-by-amd-to-accelerate-training-for-large-complex-ai-models.html). Checked 2026-10-19. Dated 5U family/eight MI300X-or-MI325X population and air-or-direct-liquid option descriptions only. Not a current offer, exhaustive supported-combination matrix, rack-density recommendation, availability, HPE service endorsement, benchmark or conversion permission.

## Related Leviathan resources

- [Dell, Supermicro and HPE: compare complete OEM systems](/articles/dell-vs-supermicro-vs-hpe-gpu-servers)
- [HGX versus DGX: distinguish platform and complete system](/articles/hgx-vs-dgx-deployment)
- [GPU memory capacity: device, platform and usable-memory limits](/articles/data-center-gpu-memory-capacity-comparison)
- [Which GPU is fastest: read workload-specific evidence](/articles/which-gpu-is-fastest-workload-benchmarks)
- [Customer-furnished equipment and materials: reconcile the delivery](/articles/customer-furnished-materials-installation-checklist)
- [MI350X and MI355X: identify the complete server and installation inputs](/articles/amd-mi350-physical-installation-readiness)

## Discuss the selected server installation

Share the exact OEM model, accelerator configuration, site location and available approved physical work package. Our team will follow up to discuss scope, requirements and availability.

[Discuss the scope](/contact?service=gpu-assembly&from=/articles/amd-mi300x-vs-nvidia-h100)